Suitability of Quaternary Deposits in Alam Area as Filing Materials in Earth Fills Dams
Main Article Content
Abstract
The Study aims to evaluate the suitability of quaternary deposits in AL-Alam area as filling materials in earth fill dams. The geotechnical properties of deposits for three stations show that the type of soil is (ML) and the curves of grain size analyses confirm the curve of Zone C., while the ratio of total dissolved salts(TDS) and gypsum contents ranges between (2.71-8.61)% and (0.18-0.68)% respectively The values of liquid limit and plastic limit ranges between (40.2-44.7)% and (10.5-13.7)% respectively. According to Iraqi specification, the deposits of station (3) are suitable for filling materials in earth dams, while the geotechnical properties of the deposits in the stations (1) and(2) are within the specifications ranges except the ratios of (TDS).
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
Tikrit Journal of Pure Science is licensed under the Creative Commons Attribution 4.0 International License, which allows users to copy, create extracts, abstracts, and new works from the article, alter and revise the article, and make commercial use of the article (including reuse and/or resale of the article by commercial entities), provided the user gives appropriate credit (with a link to the formal publication through the relevant DOI), provides a link to the license, indicates if changes were made, and the licensor is not represented as endorsing the use made of the work. The authors hold the copyright for their published work on the Tikrit J. Pure Sci. website, while Tikrit J. Pure Sci. is responsible for appreciate citation of their work, which is released under CC-BY-4.0, enabling the unrestricted use, distribution, and reproduction of an article in any medium, provided that the original work is properly cited.
References
1- Druyts, F. 1985, Testing of materials and Soils,
Hydaulic Structures, Equipment and water data
Acquisition- Vol. IV.
2- Ancold, 2000, Australian National Committee on
Large Dams Guidelines on Selection of Acceptable
Flood Capacity for Dams (march,2000).
3- Harradine, Alan, 2008, Guidelines for the
construction of earth-fill Dams.
4- Jassim ,S.Z.(1981). Early Pleistocene gravel fan of
the Tigris River from AL-Ftha to Baghdad ,Central
Iraq Jour.Geol.Scei Iraq,14,25-34.
5- Al-Khafaji, A.W., and Andersland, O.B., 1992,
Geotechnical Engineering and Soil Testing.
6- Dunn, I., Anderson, L., and Kiefer, F., (1980),
"Fundamental of Geotechnical Analysis", John Wiley
& sons inc, USA 414p.
7- ASTM-E 11 (2004), "STANDARD
SPECIFICATION FOR WOVEN WIRE TEST
SIEVE CLOTH AND TEST SIEVES .
8- ASTM, D 422-63 .,(2004)," Standard Test Method
for Particle-Size Analysis of Soils .
9- ASTM. D-421, 2004, Standard Practice for dry
preparation of soil samples for particle size analysis
and determination of soil constants.
10- ASTM, D 4318-00.,(2004) "Standard Test
Methods for Liquid Limit, Plastic Limit, and
Plasticity Index of Soils " .
11- Handbook No.60, (1959), "Diagnosis and
Improvement of Saline and Alkali Soils, Agric.", US
Department of Agriculture (USDA), Washington,
D.C.
12-National center for laboratory and construction
research (2003) specification of construction
materials No.(SORP/R5), General Specification of
Rods and Bridges ,Earth work .